Published 1996 | Version v1
Book

Off-air monitoring for PET-centers. Practical aspects

  • 1. Technical Univ. Graz, Nuclear Physics Inst., 8010 Graz (Austria)
  • 2. EG and G Berthold, 91054 Erlangen (Germany)

Description

During operation of a PET-Center, the air is contaminated by radioactivity. Apart from accidents, this contamination may be caused, for example, by neutron-induced air activity during operation of a cyclotron, leaks in the chemical process units and the use of radioactive gases on patients. Therefore, the room air as well as the waste air have to be monitored. Due to lack of experience, there is still uncertainty regarding the scope and the proper layout of such measuring systems. This paper will discuss the principle of a waste air monitoring system which features adequate sensitivity as well as the required retaining capability in case the activity is exceeded. (author)

Part of:
IRPA9: 1996 international congress on radiation protection. Proceedings. Volume 3

Additional details

Publishing Information

Publisher
Berger.
Imprint Place
Horn (Austria)
ISBN
3-9500255-4-5
Imprint Title
IRPA9: 1996 international congress on radiation protection. Proceedings. Volume 3
Imprint Pagination
697 p.
Journal Page Range
p. 553-555.

Conference

Title
9. international congress on radiation protection and general assem bly of the International Radiation Protection Association (IRPA).
Dates
14-19 Apr 1996.
Place
Vienna (Austria).

Optional Information