Impacts of thermo-optical properties on the seasonal operation of thermochromic smart window
- 1. Chongqing University of Science and Technology, Big Data Analysis and Application Research Institute, Chongqing 401331 (China)
- 2. School of Engineering, RMIT University, Melbourne 3004 (Australia)
Description
Highlights: • Inhomogeneous tinting of thermochromic glazing (TCG) is achieved by CFD simulation. • Summer/winter & sunny/cloudy conditions are analyzed to evaluate seasonal operation. • Highest overall reduction in transmitted radiation is 20.9% with 6.6% energy saving. • Best switching temperatures are at 25–35 °C for longer & sunnier summer than winter. A type of smart window using thermochromic glazing (TCG) is a promising technology for green buildings owing to the self-regulating feature and low-maintenance need. Its most important feature, thermo-optical properties that regulate the blockage of solar heat, is directly linked to the variation of surface temperatures. However, challenges from the inhomogeneity of thermo-optical properties, the coupled solar radiation and natural convection, and varying outdoor conditions all seriously hinder the understanding of its mechanism. In this paper, a validated Computational Fluid Dynamics (CFD) model achieves the simulation of inhomogeneous tinting of TCG by defining the thermo-optical properties of each finite volume according to the surface temperature. Solar radiation and natural convection at outdoor, indoor and the cavity are solved to reflect glazing temperature more accurately. The case studies compared six different switching temperatures in the range of 20 ∼ 42.5 °C with a transition gradient of 10 °C. Averaged meteorological data for both summer and winter, sunny days and cloudy days are selected to present realistic climate impacts. The result reveals the overall saving in transmitted solar radiation in summer and heating penalties in winter. It suggests the best switching temperatures for each climate condition. With the seasonal operation, the highest saving in solar heat gain is 20.9% when adopting a switching temperature of 25–35 °C, while the lowest saving can be negative, meaning TCG is not suitable for those climate zones. The proposed evaluation criteria help to quantify the applicability of TCG with the input of the summer/winter day ratio and sunny/cloudy ratio. The best region to apply TCG is where summer days are longer and winter solar radiation is significantly lower. The in-depth understanding of this temperature-sensitive process benefits the optimization of TCG in buildings, especially for its seasonal operation needs.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.enconman.2021.115058Additional details
Identifiers
- DOI
- 10.1016/j.enconman.2021.115058;
- PII
- S0196890421012346;
Publishing Information
- Journal Title
- Energy Conversion and Management
- Journal Volume
- 252
- Journal Page Range
- vp.
- ISSN
- 0196-8904
- CODEN
- ECMADL
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54033697
- Subject category
- S36: MATERIALS SCIENCE; S42: ENGINEERING;
- Descriptors DEI
- COMPUTERIZED SIMULATION; FLUID MECHANICS; GLAZING MATERIALS; HEAT; HEAT GAIN; HEATING; METEOROLOGY; NATURAL CONVECTION; OPTICAL PROPERTIES; OPTIMIZATION; RENEWABLE ENERGY SOURCES; SOLAR RADIATION; TRANSITION TEMPERATURE
- Descriptors DEC
- CONVECTION; ENERGY; ENERGY SOURCES; ENERGY TRANSFER; HEAT TRANSFER; MASS TRANSFER; MATERIALS; MECHANICS; PHYSICAL PROPERTIES; RADIATIONS; SIMULATION; STELLAR RADIATION; THERMODYNAMIC PROPERTIES