Absorbed dose distribution near tissue-equivalent matter surface irradiated by high-energy muons
Description
Presented are the results of absorbed dose measurements near tissue-equivalent matter surface irradiated by high-energy muons with an average impulse of 17 GeV/c. The measurements are carried out by a parallel plate ionization chamber within the depth range from 3.6x10-3 to 25gxcm-2. The experimental results are compared with the calculated data. Maximum divergence of experimental and calculated data in absolute values of absorbed doses for the depth range from 0.1 to 30gxcm-2 constitutes 10%. The obtained results are required to interpret the readings of film detectors in the fields of high-energy radiation as well as to analyse the component composition of the doses in the phantoms, irradiated by high-energy particles
Availability note (English)
MF available from INIS under the Report Number.Files
10421150.pdf
Files
(249.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:8b11f61288d3d71b5e350f9d358d45fd
|
249.3 kB | Preview Download |
System files
(22.9 kB)
| Name | Size | Download all |
|---|
Additional details
Additional titles
- Original title (Russian)
- Распределение поглощенной дозы вблизи поверхности тканеэквивалентного вещества облучаемой мюонами высокой энергии
Publishing Information
- Imprint Pagination
- 10 p.
- Report number
- IFVE-LRI--77-48
Conference
- Title
- 5. all-union conference on charged particle accelerators.
- Dates
- 5 - 7 Oct 1976.
- Place
- Dubna, USSR.
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 10421150
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BIOLOGICAL RADIATION EFFECTS; COMPARATIVE EVALUATIONS; GEV RANGE 10-100; IONIZATION CHAMBERS; MUON BEAMS; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; TISSUE-EQUIVALENT MATERIALS
- Descriptors DEC
- BEAMS; BIOLOGICAL EFFECTS; ENERGY RANGE; GEV RANGE; LEPTON BEAMS; MEASURING INSTRUMENTS; PARTICLE BEAMS; RADIATION DETECTORS; RADIATION EFFECTS