Design of interaction cavity for 170 GHz, 1 MW ITER gyrotron

  • 1. Gyrotron Laboratory, Microwave Tube Area, Central Electronics Engineering Research Institute, Pilani (India)
  • 2. Department of Physics, Banasthali University, Banasthali (India)

Description

In this paper the design of interaction cavity for 170 GHz, 1 MW gyrotron is presented. An in-house developed code GCOMS has been used for operating mode selection and mode competition. For 170 GHz, 1 MW gyrotron interaction cavity TE28, 7 mode excite as a operating mode at the fundamental harmonic number. The electromagnetic simulator-MAGIC, a Particle-in-Cell (PIC) code has been used for the cold cavity analysis and the beam-wave interaction. More than 1MW output power has been achieved at guiding cavity magnetic field 6.77 T. (author)

Part of:
Proceedings of the 2011 IEEE international vacuum electronics conference: book of abstracts

Additional details

Publishing Information

Publisher
Institute of Electrical and Electronics Engineers
Imprint Place
New Jersey (United States)
ISBN
978-1-4244-8659-5
Imprint Title
Proceedings of the 2011 IEEE international vacuum electronics conference: book of abstracts
Imprint Pagination
564 p.
Journal Page Range
p. 113-114

Conference

Title
12. IEEE international vacuum electronics conference
Acronym
IVEC-2011
Dates
21-24 Feb 2011
Place
Bangalore (India)

INIS

Optional Information

Notes
6 refs., 3 figs., 1 tab.; This record replaces 44037449