Published March 2008 | Version v1
Journal article

A study on error characteristics of large size electromagnetic flowmeter in the range of low velocity

  • 1. Korea Water Resources Corp., Daejeon (Korea, Republic of)
  • 2. Chungnam National Univ., Daejeon (Korea, Republic of)

Description

The large size electromagnetic flowmeter was tested to investigate the variation of its error characteristics in the range of low velocity under 0.6 m/s using flowmeter calibration system. For the two case of valve opening rate 100 % and 50 %, these tests were undertaken three times each for twelve velocity condition from 0.05 m/s to 0.6 m/s with increment of 0.05 m/s. It is shown that error characteristic of electromagnetic flowmeter was stabilized within ±0.4 % of rate both higher than 0.25 m/s of velocity condition and 50 % of valve opening position. But, measurement deviation of flowmeter for φ400 mm and φ600 mm was out of expected deviation range. It is necessary to correction with calibration. In conclusion, error characteristic of electromagnetic flowmeter wasn't changed proportion to its size

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
32
Journal Issue
3
Series
7 refs, 7 figs, 1 tab
Journal Page Range
p. 235-240
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
40052524
Subject category
S42: ENGINEERING;
Descriptors DEI
BENCH-SCALE EXPERIMENTS; CALIBRATION; ELECTROMECHANICS; ERRORS; FLOWMETERS; VALVES
Descriptors DEC
CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; MEASURING INSTRUMENTS; MECHANICS; METERS