Real time dose rate measurements with fiber optic probes based on the RL and OSL of beryllium oxide
Creators
Description
This work covers the examination of fiber optical probes based on the radioluminescence and real time optically stimulated luminescence of beryllium oxide. Experiments are carried out to determine the fundamental dosimetric and temporal properties of the system and evaluate its suitability for dose rate measurements in brachytherapy and other applications using non-pulsed radiation fields. For this purpose the responses of the radioluminescence and optically stimulated luminescence signal have been investigated in the dose rate range of 20 mGy/h to 3.6 Gy/h and for doses of 1 mGy up to 6 Gy. Furthermore, a new, efficient analysis procedure, the double phase reference summing, is introduced, leading to a real time optically stimulated luminescence signal. This method allows a complete compensation of the stem effect during the measurement. In contrast to previous works, the stimulation of the 1 mm cylindrical beryllium oxide detectors is performed with a symmetric function during irradiation. The investigated dose rates range from 0.3 to 3.6 Gy/h. The real time optically stimulated luminescence signal of beryllium oxide shows a dependency on both the dose rate and the applied dose. To overcome the problem of dose dependency, further experiments using higher stimulation intensities have to follow. - Highlights: • RL and OSL measurements with BeO extended to low dose (rate) range. • A new method to obtain the real time OSL: Dual Phase Reference Summing. • Real time OSL signal shows both dose and dose rate dependency. • Real time OSL enables a complete discrimination of the stem effect.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radmeas.2016.01.015Additional details
Identifiers
- DOI
- 10.1016/j.radmeas.2016.01.015;
- PII
- S1350-4487(16)30015-4;
Publishing Information
- Journal Title
- Radiation Measurements
- Journal Volume
- 90
- Journal Page Range
- p. 201-204
- ISSN
- 1350-4487
- CODEN
- RMEAEP
Conference
- Title
- 9. international conference on luminescent detectors and transformers of ionizing radiation
- Acronym
- LUMDETR 2015
- Dates
- 20-25 Sep 2015
- Place
- Tartu (Estonia)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48099900
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BERYLLIUM OXIDES; CYLINDRICAL CONFIGURATION; DOSE RATES; FIBER OPTICS; PROBES; PULSES; RADIOLUMINESCENCE; SIGNALS
- Descriptors DEC
- ALKALINE EARTH METAL COMPOUNDS; BERYLLIUM COMPOUNDS; CHALCOGENIDES; CONFIGURATION; EMISSION; LUMINESCENCE; OPTICS; OXIDES; OXYGEN COMPOUNDS; PHOTON EMISSION
Optional Information
- Copyright
- Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.