DOEL 4-loss of external load transient

  • 1. Nuclear Science Dept., Tractebel, Brussels (Belgium)
  • 2. Laborelec, Linkebeek (Belgium)

Description

An analysis is presented of a loss of external load transient, performed at the DOEL-4 plant during the commissioning period. The availability of a high quality data acquisition system, combined with a detailed numerical simulation of the transient by means of the RELAP-5 code did allow a detailed qualitative and quantitative analysis of the complex interacting plant phenomena. Both are indispensable in optimizing the plant control systems to assure a smooth and stable transition from full load to house load without reactor trip

Additional details

Additional titles

Subtitle (English)
Simulation and analysis

Publishing Information

Publisher
American Nuclear Society.
Imprint Place
La Grange Park, IL (USA)
ISBN
0-89448-136-3
Imprint Title
Anticipated and abnormal transients in nuclear power plants
Imprint Pagination
vp.
Journal Page Range
p. XIII-52-XII-59.

Conference

Title
Topical meeting on anticipated and abnormal transients in nuclear power plants.
Dates
12-15 Apr 1987.
Place
Atlanta, GA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
22077493
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPUTER CODES; DATA ACQUISITION SYSTEMS; DOEL-4 REACTOR; OPTIMIZATION; REACTOR COMMISSIONING; REACTOR CONTROL SYSTEMS; SIMULATION; TRANSIENTS
Descriptors DEC
CONTROL SYSTEMS; ENRICHED URANIUM REACTORS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS

Optional Information

Secondary number(s)
CONF-870418--.