Published March 13, 2006 | Version v1
Report

The PEP-II Lower Pressure HER Vacuum Chamber

Description

This new vacuum chamber has been installed from 12 to 21 meters upstream of the BaBar detector in the PEP-II High Energy Ring (HER) to reduce lost particle backgrounds. The backgrounds from HER now dominate the backgrounds in the BaBar detector and the present vacuum pressure is 1 x 10-9 Torr. The new chamber will increase the pumping significantly by adding 18 x 2000 l/s titanium sublimation pumps to the existing 5 x 440 l/s ion pumps, and is expected to reduce the pressure by about a factor of five. Features of the chamber include improved water cooling, improved vacuum conductance through copper RF screens featuring over 15,000 small square holes and the ability to sublimate titanium while the beam is still on

Availability note (English)

Available from http://www.slac.stanford.edu/cgi-wrap/pubpage?slac-pub-11751.html; OSTI as DE00877437; PURL: https://www.osti.gov/servlets/purl/877437-mIGE2d/

Additional details

Publishing Information

Imprint Pagination
3 p.
Report number
SLAC-PUB--11751

Conference

Title
18. International Conference on High-Energy Accelerators (HEACC 2001)
Dates
26-30 Mar 2001
Place
Tsukuba (Japan)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
37066627
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ACCELERATORS; BEAMS; COPPER; PRESSURE CONTROL; PRESSURE RANGE NANO PA; RADIATION DETECTORS; TITANIUM; VACUUM PUMPS
Descriptors DEC
CONTROL; ELEMENTS; EQUIPMENT; LABORATORY EQUIPMENT; MEASURING INSTRUMENTS; METALS; PRESSURE RANGE; PUMPS; TRANSITION ELEMENTS

Optional Information

Contract/Grant/Project number
AC02-76SF00515
Funding organization
US Department of Energy (United States)