Comparative analysis of the radiation shield effect in an abdominal CT scan
Creators
- 1. Daegu Health College, Daegu (Korea, Republic of)
- 2. Daegu Fatima Hospital, Daegu (Korea, Republic of)
- 3. Chosun University, Gwangju (Korea, Republic of)
- 4. Gwangju Health University, Gwangju (Korea, Republic of)
- 5. Konyang University, Daejeon (Korea, Republic of)
Description
This study measured and compared the dose on the eyeballs and the thyroid with and without the use of a shield by applying the abdominal examination protocol used in an actual examination to a 64-channel computed tomography (CT) scan. A dummy phantom manufactured from acryl was used to measure the dose to the eyeballs and the thyroid of a patient during a thoraco-abdominal CT scan. The dose was measured using three dosimeters (optically-stimulated luminescence dosimeter (OSLD), thermoluminescence dosimeter (TLD) and photoluminescence dosimeter (PLD)) attached to the surfaces of three parts (left and right eyeballs and thyroid) in a phantom with and without the use of a shield for the eyeballs and the thyroid. Two types of shields (1-mm barium shielding sheet and 1-mm tungsten shielding sheet) were used for the measurements. The goggles and the lead shield, which are normally used in clinical practice, were used to compare the shield ratios of the shields. According to the results of the measurements made by using the OSLD, the shield ratios of the barium and the tungsten sheets were in the range of 34 - 36%. The measurements made by using the TLD showed that the shield ratio of the barium sheet was 6.25% higher than that of the tungsten sheet. When the PLD was used for the measurement, the shield ratio of the barium sheet was 33.34%, which was equivalent to that of the tungsten sheet. These results confirmed that the cheap barium sheet had a better shielding effect than the expensive tungsten sheet.
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Physical Society
- Journal Volume
- 64
- Journal Issue
- 6
- Series
- 17 refs, 4 figs, 2 tabs
- Journal Page Range
- p. 929-935
- ISSN
- 0374-4884
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 46033649
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABDOMEN; BARIUM; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; LEAD; RADIATION DOSES; SHIELDING; THERMOLUMINESCENT DOSEMETERS; THYROID; TUNGSTEN
- Descriptors DEC
- ALKALINE EARTH METALS; BODY; DIAGNOSTIC TECHNIQUES; DOSEMETERS; DOSES; ELEMENTS; ENDOCRINE GLANDS; EVALUATION; GLANDS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; METALS; ORGANS; REFRACTORY METALS; TOMOGRAPHY; TRANSITION ELEMENTS