Published April 1982
| Version v1
Report
Open
Switching tests for the LCTF protective dump circuit
Description
Each of the six coils in the Large Coil Test Facility (LCTF) has a separate power supply, dump resistor, and switching circuit. Each switching circuit contains five switches, two of which are redundant. The three remaining switches perform separate duties in an emergency dump situation. These three switches were tested to determine their ability to meet the LCTF conditions
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01 as DE82015073.Files
14718397.pdf
Files
(499.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:3ddcf17730befc079e8db1be4c5a99a9
|
499.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 42 p.
- Report number
- LA--9261-MS
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14718397
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
- Descriptors DEI
- ENERGY TRANSFER; PERFORMANCE TESTING; POWER SUPPLIES; RESEARCH PROGRAMS; SUPERCONDUCTING MAGNETS; SWITCHES
- Descriptors DEC
- ELECTRICAL EQUIPMENT; ELECTROMAGNETS; ELECTRONIC EQUIPMENT; EQUIPMENT; MAGNETS; SUPERCONDUCTING DEVICES; TESTING