Published March 2020 | Version v1
Journal article

Characteristics of dust-collection efficiency and ozone emission by high-voltage electrode shape of electrostatic precipitator for subway tunnel environment

  • 1. Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)
  • 2. Korea Institute of Science and Technology, Seoul (Korea, Republic of)
  • 3. Hanyang University, Seoul (Korea, Republic of)

Description

The air pollution level of particulate matters in subway tunnel environments is severe. The present study conducted experimental measurements and analyses on dust-collection efficiencies and ozone emission rates in a lab-scale wind tunnel to determine a high-voltage electrode shape suitable for an electrostatic precipitator to remove airborne particles in subway tunnels. Six high-voltage electrode shapes (saw-type, few-saw-type, short-saw-type, tree-type, wave-type, and spike-type) were tested. The results indicate that while breakdown voltage of the spike-type high-voltage electrode was 66 % of other electrode shapes, its dust-collection efficiency per unit voltage was similar to that of other electrode shapes. However, the dust-collection efficiency per unit of power in the spike-type high-voltage electrode was significantly low. Moreover, the wave-type high-voltage electrode shape had 20 % lower dust-collection efficiency than the saw-type and tree-type high-voltage electrode shapes under conditions of low voltage and high flow velocities. Ozone emission rates for all shapes increased proportionally to the electric current. However, ozone emission rates for each high-voltage electrode shape are varied as 12–23 μg/s per mA. The saw-type and tree-type high-voltage electrode shapes were superior in terms of dust collection, 90 % collection efficiency was shown at about 1.5 W/(m/s)2. The saw-type had a lower ozone emission rate (16.4 μg/s per mA) than the tree-type (19.6 μg/s per mA). Thus, the saw-type shape was the most suitable as a high-voltage electrode in the electrostatic precipitator for removing airborne particles in a subway. The results also indicate that both dust-collection efficiencies and ozone emission rates should be evaluated concurrently when evaluating electrostatic precipitator high-voltage electrodes.

Additional details

Publishing Information

Journal Title
Journal of Mechanical Science and Technology
Journal Volume
34
Journal Issue
3
Series
41 refs, 12 figs
Journal Page Range
p. 1351-1363
ISSN
1738-494X

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
52031785
Subject category
S54: ENVIRONMENTAL SCIENCES; S42: ENGINEERING;
Descriptors DEI
AIR POLLUTION CONTROL; AIR POLLUTION MONITORING; DUST COLLECTORS; DUSTS; EFFICIENCY; ELECTRODES; ELECTROSTATIC PRECIPITATORS; EMISSION; OZONE; PARTICULATES; SHAPE
Descriptors DEC
CONTROL; EQUIPMENT; MONITORING; PARTICLES; POLLUTION CONTROL; POLLUTION CONTROL EQUIPMENT