Published July 5, 1995 | Version v1
Journal article

On the optimal choice of microwave systems for future linear colliders

  • 1. Institute for Plasma Research, University of Maryland, College Park, Maryland 20742 (United States)

Description

Future TeV linear colliders will require electron sources with GHz frequency ranges and MWatt power sources. Problems caused by the specific features of such RF accelerating structures are discussed. Breakdown limits of klystrons and gyroklystrons are discussed. A study of a fourth harmonic, three-cavity gyroklystron at 34 GHz is discussed

Additional details

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
337
Journal Issue
1
Journal Page Range
p. 16-24.
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
Pulsed radio frequency sources for linear colliders.
Dates
2-7 Oct 1994.
Place
Long Island, NY (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
27022344
Subject category
S43: PARTICLE ACCELERATORS; S43: PARTICLE ACCELERATORS; S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DESIGN; GYROCONS; KLYSTRONS; LINEAR COLLIDERS; MICROWAVE RADIATION; RADIATION SOURCES; RF SYSTEMS
Descriptors DEC
ACCELERATORS; ELECTROMAGNETIC RADIATION; ELECTRON TUBES; ELECTRONIC EQUIPMENT; EQUIPMENT; LINEAR ACCELERATORS; MICROWAVE EQUIPMENT; MICROWAVE TUBES; RADIATIONS

Optional Information

Secondary number(s)
CONF-9410218--.