Published February 2008 | Version v1
Journal article

Amplification of spontaneous emission of neon-like argon in a fast gas-filled capillary discharge

  • 1. Academy of Sciences of the Czech Republic, Institute of Plasma Physics (Czech Republic)
  • 2. Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation)

Description

The evolution of the CAPEX facility and its basic diagnostics are described. The experiments carried out in the last modification of this facility accomplished with the demonstration of amplified spontaneous emission of neon-like argon (Ar8+) at the wavelength 46.88 nm. The first version of the facility, CAPEX1, operated with a plastic capillary and had a short high-power passive prepulse and an imperfect gas-filling system. In the second version, CAPEX2, a ceramic capillary was used, the prepulse amplitude was lowered, and the gas-filling system was improved. In the third, most successful version, CAPEX3, the capillary bending was reduced, a longer external prepulse was used, and the gas-filling system was further optimized. For each version, results of X-ray measurements are presented and interpreted.

Additional details

Identifiers

Publishing Information

Journal Title
Plasma Physics Reports
Journal Volume
34
Journal Issue
2
Journal Page Range
p. 162-168
ISSN
1063-780X
CODEN
PPHREM

INIS

Optional Information

Copyright
Copyright (c) 2008 Pleiades Publishing, Ltd.