Published 1994 | Version v1
Book

Inservice Inspections of steam generators in NPP with VVER 440 at NPP Bohunice

  • 1. Nuclear Power Plant Research Institute. Trnava (El Salvador)

Description

Problems related to the insurance of the steam generator performance are, similarly as by the other NPP operators, one of the first ranking tasks at the operator of 4 Units in the NPP Bohunice. Material integrity inspections of the chosen steam generator parts is one of many tasks related to this issue. Inspection is ensured by the periodical inservice inspections. Commissioning of NPP Bohunice units was in years: Unit 1-1978, Unit 2-1980, Unit 3-1984, Unit 4-1985 These 24 steam generators represent more than 433 steam generator-years of operational experience. (Author)

Part of:
Steam generator problems and replacement

Additional details

Publishing Information

Publisher
CIEMAT.
Imprint Place
Madrid (Spain)
Imprint Title
IAEA specialist's meeting on steam generator problems and replacement
Imprint Pagination
653 p.
Journal Page Range
p. 345-355.

Conference

Title
IAEA specialist's meeting on steam generator problems and replacement.
Dates
13-16 Dec 1993.
Place
Madrid (Spain).

Optional Information