Analysis on the Calculating of Air Leakage Threshold which Caused the Condenser Vacuum Deterioration
Creators
- 1. State Grid Shandong Electric Power Research Institute Jinan, China. (China)
Description
There is an air leakage threshold under certain condenser heat load and air ejector output. When the amount of air leakage is less than the threshold, the condenser pressure is essentially the same, we can maintain a stable condenser vacuum, once exceed the threshold, condenser pressure begin to gradually larger, condenser vacuum will deteriorate. Considered the air leakage influences on the heat transfer coefficient of condenser, this paper had been established the one-dimensional steady-state heat transfer model of condenser to obtain the condenser pressure curve along with the amount of air leakage, the turning point on the curve is the air leakage threshold. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1757-899X/452/3/032094Additional details
Identifiers
Publishing Information
- Journal Title
- IOP Conference Series. Materials Science and Engineering (Online)
- Journal Volume
- 452
- Journal Issue
- 3
- Journal Page Range
- [10 p.]
- ISSN
- 1757-899X
Conference
- Title
- 3. International Conference on Insulating Materials, Material Application and Electrical Engineering
- Dates
- 15-16 Sep 2018
- Place
- Melbourne (Australia)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52102463
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COMPRESSORS; HEAT; HEAT EXCHANGERS; HEAT TRANSFER; HEATING LOAD; ONE-DIMENSIONAL CALCULATIONS; STEADY-STATE CONDITIONS; VAPOR CONDENSERS
- Descriptors DEC
- ENERGY; ENERGY TRANSFER