Published December 1, 2018 | Version v1
Journal article

Analysis on the Calculating of Air Leakage Threshold which Caused the Condenser Vacuum Deterioration

  • 1. State Grid Shandong Electric Power Research Institute Jinan, China. (China)

Description

There is an air leakage threshold under certain condenser heat load and air ejector output. When the amount of air leakage is less than the threshold, the condenser pressure is essentially the same, we can maintain a stable condenser vacuum, once exceed the threshold, condenser pressure begin to gradually larger, condenser vacuum will deteriorate. Considered the air leakage influences on the heat transfer coefficient of condenser, this paper had been established the one-dimensional steady-state heat transfer model of condenser to obtain the condenser pressure curve along with the amount of air leakage, the turning point on the curve is the air leakage threshold. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1757-899X/452/3/032094

Additional details

Publishing Information

Journal Title
IOP Conference Series. Materials Science and Engineering (Online)
Journal Volume
452
Journal Issue
3
Journal Page Range
[10 p.]
ISSN
1757-899X

Conference

Title
3. International Conference on Insulating Materials, Material Application and Electrical Engineering
Dates
15-16 Sep 2018
Place
Melbourne (Australia)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52102463
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPRESSORS; HEAT; HEAT EXCHANGERS; HEAT TRANSFER; HEATING LOAD; ONE-DIMENSIONAL CALCULATIONS; STEADY-STATE CONDITIONS; VAPOR CONDENSERS
Descriptors DEC
ENERGY; ENERGY TRANSFER