Published December 1999 | Version v1
Journal article

The necessity of steam generator high capacity blowdown operation for KSNP

Description

High capacity blowdown concept is applied in steam generator design for Korea Standard Nuclear Power Plant (KSNP) to remove sludge on tubesheet before solidification. NSSS system design adopted the operation mode as one of performance related design basis events, and proved that no adverse results happen such as reactor trip during high capacity blowdown operation. But KEPCO don't want to perform the operation for fearing of power reduction and the possibility of reactor trip due to SG level fluctuation. This report presents the performance analysis results for KSNP and the operation data for PVNGS related with the operation, to confirm the necessity of high capacity blowdown operation. (author)

Additional details

Publishing Information

Journal Title
Power Engineering
Journal Volume
10
Journal Issue
2
Journal Page Range
p. 84-89
ISSN
1225-8016

Optional Information

Notes
15 refs., 1 tab., 3 figs.