Published 2004 | Version v1
Journal article

The VEPP-5 injection complex modulator revision and operational experience

  • 1. The Budker Institute of Nuclear Physics, Novosibirsk (Russian Federation)

Description

For the VEPP-5 injection complex klystrons (5045, SLAC Lab., USA) power supply the four modulators producing a pulse voltage of 23.5 kV, a current of 6.3 kA, a pulse-top-duration of 3.7 μs are used. The results of the thyratrons TGI1-2500/50 and TGI1-5000/50A long-term exploitation in the VEPP-5 injection complex modulators are presented. The test results of the thyratron TGI1-2500/50 operating in the mode of more then twice pulse current overload at the nominal mode of modulator operation are also presented

Additional details

Publishing Information

Journal Title
Voprosy Atomnoj Nauki i Tekhniki. Yaderno-fizicheskie issledovaniya
Journal Issue
no.2,43
Journal Page Range
p. 99-101
ISSN
1562-6016