Published 1979 | Version v1
Report Open

Mantle treatment of Hodkin's disease with 60Co gamma rays

  • 1. Lund Univ. (Sweden). Radiofysiska Institutionen

Description

60Co mantle beams were used in the radiation treatment of patients| with Hodgkin's disease. A technique using beam-flattening filters is described. The dosimetry was based on dose plans drawn up manually for each patient. The good dosimetric accuracy of the method was verified by in vivo measurements of absorbed dose at the oesophagi of 60 patients. Split-course treatment with 40 Gy was given in 27 fractions over 71 days. Results and side-effects in 90 patients are analyzed. The local recurrence rate was 3 %. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

10480278.pdf

Files (750.0 kB)

Name Size Download all
md5:82073d4171436770bb02a19f7406872b
750.0 kB Preview Download

Additional details

Additional titles

Subtitle (English)
Technique, dosimetry and medical application

Publishing Information

Imprint Pagination
34 p.
Report number
LUNFD6-NFRA--1008/1-34/(1979)

Optional Information

Secondary number(s)
LUMEDW-MERI--1008/1-34/(1979).