Published 1900 | Version v1
Book

NUKAB system use with the PICKER DYNA CAMERA II

  • 1. Centre Hospitalier Universitaire, 34 - Montpellier (France)
  • 2. Centre Regional de Lutte contre le Cancer, 34 - Montpellier (France)

Description

Present-day data processing units connected to scintillation gamma cameras can make use of cabled programme or recorded programme systems. The NUKAB system calls on the latter technique. The central element of the data processing unit, connected to the PICKER DYNA CAMERA II output, consists of a DIGITAL PDP 8E computer with 12-bit technological words. The use of a 12-bit technological format restricts the possibilities of digitalisation, 64x64 images representing the practical limit. However the NUKAB system appears well suited to the processing of data from gamma cameras at present in service. The addition of output terminals of the tracing panel type should widen the possibilities of the system. It seems that the 64x64 format is not a handicap in view of the resolution power of the detectors

Abstract (French)

Actuellement les unites de traitement de l'information reliees aux gamma cameras a scintillations peuvent se concevoir au moyen de systemes a programmes cables ou de programmes enregistres. Le systeme NUKAB fait appel a cette derniere technique. L'element central de l'unite de traitement de l'information branchee en sortie DYNA CAMERA II PICKER est forme d'un ordinateur DIGITAL PDP 8E a mots technologiques de 12 bits. L'utilisation d'un format technologique a 12 bits limite les possibilites de digitalisation. Pratiquement on se trouve limite a des images 64x64. Neanmoins, le systeme NUKAB parait bien adapte au traitement des informations provenant des gamma cameras actuellement en service. L'adjonction de peripheriques de sortie du genre table tracante devrait etendre les qualites du systeme. Il ne semble pas que le format 64x64 soit un handicap compte tenu du pouvoir de resolution des detecteurs

Additional details

Additional titles

Original title (French)
Systeme NUKAB utilisation avec la DYNACAMERA II PICKER

Publishing Information

Publisher
Centre Europeen de Promotion Medicale.
Imprint Place
Lyon, France
Imprint Title
Scintillation cameras. Data processing and display systems
Imprint Pagination
3p.

Conference

Title
European technological congress on nuclear medicine.
Dates
24 Jan 1974.
Place
Lyon, France.

INIS

Country of Publication
France
Country of Input or Organization
France
INIS RN
7270705
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DATA ACQUISITION SYSTEMS; DATA PROCESSING; DISPLAY DEVICES; GAMMA CAMERAS; SCINTISCANNING
Descriptors DEC
CAMERAS; COMPUTER-GRAPHICS DEVICES; COUNTING TECHNIQUES; DIAGNOSTIC TECHNIQUES; MEDICINE; NUCLEAR MEDICINE; RADIOISOTOPE SCANNING

Optional Information

Notes
Imprint:Cameras a scintillation. Dispositifs de traitement et de restitution de l'information.;Congres technologique europeen de medecine nucleaire. Lyon, France, 24-26 janvier 1974.