Published 1976
| Version v1
Report
Restricted
Automated fluorescent excitation analysis in medicine using radioisotopic excitation sources
- 1. Univ. of California, San Francisco
Description
An automated x-ray fluorescence system has been developed for application in clinical and investigative practice. The optimization of its major components permits the rapid and accurate quantitation of low levels of selected tracers in a cost-effective manner
Files
Additional details
Publishing Information
- Imprint Title
- Proceedings of ERDA symposium on x- and gamma-ray sources and applications
- Imprint Pagination
- p. 118-121.
- Report number
- CONF-760539--
Conference
- Title
- ERDA symposium on x- and gamma-ray sources and applications.
- Dates
- 19 May 1976.
- Place
- Ann Arbor, Michigan, United States of America (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 8310456
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AUTOMATION; DIAGNOSTIC TECHNIQUES; METABOLIC DISEASES; PATIENTS; TRACER TECHNIQUES; X-RAY FLUORESCENCE ANALYSIS
- Descriptors DEC
- CHEMICAL ANALYSIS; DISEASES; ISOTOPE APPLICATIONS; NONDESTRUCTIVE ANALYSIS; X-RAY EMISSION ANALYSIS