The problem of determining the maximum overspeed of saturated steam turbines after sudden full load rejection is discussed. The assumptions and concepts of two essential groups of methods of overspeed calculations are compared. A more general approach is utilized for the verification of some assumptions and parameter values of simplified methods. The computation results of a sudden load rejection process obtained with the use of both discussed groups of methods are compared. (author)

Additional details

Additional titles

Original title (Polish)
Wyznaczanie maksymalnej predkosci obrotowej turbin dla elektrowni jadrowych po naglym zrzucie obciazenia

Publishing Information

Journal Title
Arch. Energ.
Journal Volume
13
Journal Issue
4
Series
Published in Sep 1985.;Arch. Energ.
Journal Page Range
275-284
ISSN
0066-684X
CODEN
AREGB

INIS

Country of Publication
Poland
Country of Input or Organization
Poland
INIS RN
18014239
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
NUCLEAR POWER PLANTS; PERFORMANCE; REACTOR COOLING SYSTEMS; SATURATION; STEAM; STEAM TURBINES
Descriptors DEC
COOLING SYSTEMS; NUCLEAR FACILITIES; POWER PLANTS; REACTOR COMPONENTS; THERMAL POWER PLANTS; TURBINES