Unintended Delivery of Surgical Towel Fibers into a Vein Graft During Cardiac Catheterization
- 1. Department of Cardiology, Geisinger Medical Center, 100 North Academy Drive, Danville, PA, (United States)
Description
Foreign body introduction during coronary stent delivery is an uncommon, yet potentially fatal, complication of coronary angiography and interventions. Inadvertent introduction of gauze fibers, starch granules and other foreign materials into circulation has been reported in literature. The introduction of inorganic surgical debris can cause distal embolization, vessel occlusion and wall infiltration causing infarction, acute stenosis and granulomatous reaction. This report describes a case of successful extraction of inorganic blue filamentous material during coronary vein graft intervention detected as a filling defect in a filter during coronary vein graft intervention. The specimen represented fibers from blue surgical towels used on sterile field during cardiac catheterization.
Additional details
Identifiers
- DOI
- 10.1016/j.carrev.2019.02.024;
- PII
- S1553838919301575;
Publishing Information
- Journal Title
- Cardiovascular Revascularization Medicine (Print)
- Journal Volume
- 20
- Journal Issue
- 11
- Journal Page Range
- p. 9-12
- ISSN
- 1553-8389
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 55052324
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CORONARIES; EXTRACTION; GRAFTS; SURGERY; VASCULAR DISEASES; VEINS
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; SEPARATION PROCESSES; TRANSPLANTS
Optional Information
- Copyright
- Copyright (c) 2019 Elsevier Inc. All rights reserved.