Unintended Delivery of Surgical Towel Fibers into a Vein Graft During Cardiac Catheterization

  • 1. Department of Cardiology, Geisinger Medical Center, 100 North Academy Drive, Danville, PA, (United States)

Description

Foreign body introduction during coronary stent delivery is an uncommon, yet potentially fatal, complication of coronary angiography and interventions. Inadvertent introduction of gauze fibers, starch granules and other foreign materials into circulation has been reported in literature. The introduction of inorganic surgical debris can cause distal embolization, vessel occlusion and wall infiltration causing infarction, acute stenosis and granulomatous reaction. This report describes a case of successful extraction of inorganic blue filamentous material during coronary vein graft intervention detected as a filling defect in a filter during coronary vein graft intervention. The specimen represented fibers from blue surgical towels used on sterile field during cardiac catheterization.

Additional details

Identifiers

DOI
10.1016/j.carrev.2019.02.024;
PII
S1553838919301575;

Publishing Information

Journal Title
Cardiovascular Revascularization Medicine (Print)
Journal Volume
20
Journal Issue
11
Journal Page Range
p. 9-12
ISSN
1553-8389

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
55052324
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; CORONARIES; EXTRACTION; GRAFTS; SURGERY; VASCULAR DISEASES; VEINS
Descriptors DEC
ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; SEPARATION PROCESSES; TRANSPLANTS

Optional Information

Copyright
Copyright (c) 2019 Elsevier Inc. All rights reserved.