Background and Purpose
To describe our first experience using a small stent retriever specifically designed for thrombectomy in cerebral arteries with a small caliber (Acandis APERIO® 3.5/28) in patients with acute ischemic stroke.Materials and Methods
All patients with an acute ischemic stroke, who underwent endovascular recanalization using the APERIO® thrombectomy device with a diameter of 3.5 mm, were identified in retrospect and included in the present analysis. Demographic and clinical data as well as data on the procedures performed were collected (patient sex, mean age, NIHSS, mRS, TICI score, and complications).
Results
Stent retriever-based thrombectomy with the Aperio® 3.5/28 alone (n = 10 vessels) or in combination with other devices (n = 13 vessels) was performed in 22 acute stroke patients with embolic occlusions of distal branches of the anterior and posterior circulations (median NIHSS = 8.5). For vessels treated with the Aperio® 3.5/28, we achieved a TICI 2b/3 reperfusion rate of 73.9%. One patient suffered a symptomatic intracerebral hemorrhage after thrombectomy; otherwise, no procedure-related complications were seen.
Conclusion
Our data suggest that mechanical thrombectomy of distal cerebral artery occlusions with the Aperio® 3.5/28 is feasible and in general safe, thus offering a promising option for endovascular stroke therapy. However, multicentric studies with larger patient cohorts are necessary to evaluate the clinical benefit.
Additional details
Identifiers
Publishing Information
- Journal Title
- Cardiovascular and Interventional Radiology
- Journal Volume
- 42
- Journal Issue
- 1
- Journal Page Range
- p. 101-109
- ISSN
- 0174-1551
- CODEN
- CAIRDG
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 51117753
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CEREBRAL ARTERIES; CLINICAL TRIALS; COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; EMBOLI; HEMORRHAGE; ISCHEMIA; NMR IMAGING; PATIENTS; SURGERY; VEINS
- Descriptors DEC
- ANEMIAS; ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; HEMIC DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; RADIOLOGY; SYMPTOMS; TESTING; TOMOGRAPHY; VASCULAR DISEASES
Optional Information
- Copyright
- Copyright (c) 2019 Springer Science+Business Media, LLC, part of Springer Nature and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE)
- Notes
- http://www.springer-ny.com