Shielding effect of lead glasses on radiologists' eye lens exposure in interventional procedures
- 1. Fudan University Shanghai Cancer Center, Shanghai 200032 (China)
- 2. Institute of Radiation Medicine, Fudan University, 2094 Xietu Road, Shanghai 200032 (China)
- 3. Wuxi No. 4 People's Hospital, Jiangnan University, Wuxi, Jiangsu 214062 (China)
- 4. Nuclear Engineering and Engineering Physics Program, Rensselaer Polytechnic Institute, Troy, NY 12180 (United States)
Description
To study the shielding effect of radiologists' eye lens with lead glasses of different equivalent thicknesses and sizes in interventional radiology procedures. Using the human voxel phantom with a more accurate model of the eye and MCNPX software, eye lens doses of the radiologists who wearing different kinds of lead glasses were simulated, different beam projections were taken into consideration during the simulation. Measurements were also performed with the physical model to verify simulation results. Simulation results showed that the eye lens doses were reduced by a factor from 3 to 9 when wearing a 20 cm2-sized lead glasses with the equivalent thickness ranging from 0.1 to 1.0 mm Pb. The increase of dose reduction factor (DRF) was not significant whenever increase the lead equivalent of glasses of which larger than 0.35 mm. Furthermore, the DRF was proportional to the size of glass lens from 6 to 30 cm2 with the same lead equivalent. The simulation results were in well agreements with the measured ones. For more reasonable and effective protection of the eye lens of interventional radiologists, a pair of glasses with a lead equivalent of 0.5 mm Pb and large-sized (at least 27 cm2 per glass) lens are recommended (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncw098Additional details
Identifiers
- DOI
- 10.1093/rpd/ncw098;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 174
- Journal Issue
- 1
- Journal Page Range
- p. 136-140
- ISSN
- 0144-8420
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 48062182
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BEAMS; BIOMEDICAL RADIOGRAPHY; COMPUTER CODES; CRYSTALLINE LENS; GLASS; LEAD; PHANTOMS; RADIATION DOSES; RADIOPROTECTIVE SUBSTANCES; SAFETY; SHIELDING; SIMULATION; THICKNESS
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DIMENSIONS; DOSES; DRUGS; ELEMENTS; EYES; FACE; HEAD; MEDICINE; METALS; MOCKUP; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPONSE MODIFYING FACTORS; SENSE ORGANS; STRUCTURAL MODELS
Optional Information
- Notes
- 16 refs.