Published March 1978 | Version v1
Journal article

Missing liver image in the radiocolloid scintigram

  • 1. Technische Univ. Muenchen (Germany, F.R.). 1. Medizinische Klinik und Poliklinik
  • 2. Technische Univ. Muenchen (Germany, F.R.). Nuklearmedizinische Klinik und Poliklinik

Description

In a liver scintiscan with sulphur colloid carried out in the usual way, a nearly exclusive concentration of the radiopharmaceutical in the spleen without a recognizable liver activity pattern could be observed. The pulserate relation between the liver region and the spleen maximum was 1:11. An artefact in the preparation of the sulphur colloid could be excluded. A colloid distribution di.turbance of such extent was, according to the author, not reported in literature yet, thus giving him reason to deal with this case in this paper. (orig./MG)

Abstract (German)

Bei einer in ueblicher Technik durchgefuehrten Leberszintigraphie mit Schwefelkolloid wurde eine nahezu ausschliessliche Raffung des Radiopharmazeutikums in der Milz ohne Erkennbarkeit des Leberaktivitaetsmusters beobachtet. Das Impulsratenverhaeltnis zwischen Leberbereich und Milzmaximum betrug 1:11. Ein Artefakt bei der Praeparation des Schwefelkolloids konnte ausgeschlossen werden. Eine Kolloidverteilungsstoerung dieses Ausmasses ist nach Ansicht des Autors bisher im Schrifttum nicht mitgeteilt worden und veranlasst ihn den Fall im folgenden vorzustellen. (orig./MG)

Additional details

Additional titles

Original title (German)
Fehlende Leberdarstellung im Radiokolloid-Szintigramm

Publishing Information

Journal Title
Nucl.-Med.
Journal Volume
17
Journal Issue
1
Series
Nucl.-Med.
Journal Page Range
41-42