Published March 1, 1988 | Version v1
Journal article

CDF calorimetry

  • 1. Fermi National Accelerator Lab., Batavia, IL (USA)

Description

The Collider Detector at Fermilab (CDF) is a large detector built to study 2 TeV anti pp collisions at the Fermilab Tevatron. The calorimetry, which has polar angle coverage from 20 to 1780, and complete azimuthal coverage within this region, forms the subject of this paper. It consists of both electromagnetic shower counters (EM calorimeters) and hadron calorimeters, and is segmented into about 5 000 'towers' or solid angle elements. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
265
Journal Issue
1/2
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
186-199
ISSN
0168-9002
CODEN
NIMAE

Conference

Title
4. international conference on advances in experimental methods for colliding beam physics.
Dates
9-13 Mar 1987.
Place
Stanford, CA (USA).

Optional Information

Collaborations
CDF Collaboration.