Development of a pimary coolant TTF flowmeter
Description
The report describes a contact free flowmeter system designed for primary flow measurement in PWRs. The real-time multichannel signal processing is based on transit time flow-metering (TTF) technique. A year's application at the Paks PWR, Hungary, shows that the statistical error of the measuring system is less than 2%. The system, known as CORR-FLOWsup(R), is recommended for primary flow-rate calibration in PWRs. (author)
Availability note (English)
MF available from INIS under the Report Number.Files
16050467.pdf
Files
(500.8 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:8cdab59fee2cad103a564aa7bf90ac24
|
500.8 kB | Preview Download |
Additional details
Publishing Information
- ISBN
- 963 372 296 9
- Imprint Pagination
- 20 p.
- Report number
- KFKI--1984-104
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 16050467
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- FLOW RATE; FLOWMETERS; PAKS-1 REACTOR; PRIMARY COOLANT CIRCUITS; PWR TYPE REACTORS
- Descriptors DEC
- COOLING SYSTEMS; ENRICHED URANIUM REACTORS; MEASURING INSTRUMENTS; POWER REACTORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; WWER TYPE REACTORS
Optional Information
- Notes
- 5 refs.; 6 figs.