Published April 2016 | Version v1
Journal article

Feasibility study on flow test procedure for AP1000 accumulator discharge lines

  • 1. State Nuclear Power Engineering Company, Shanghai (China)

Description

In this paper, the process level and injection flow rate during the accumulator discharge lines flow test are calculated with an iterative method, and the effectiveness of the test settings is evaluated against the results. It shows that the initial parameters chosen by the procedure are appropriate, and they can maintain the two check valves on the injection lines fully open. After the motor-operated valve is fully open, the injection time is still long enough for obtaining data to calculate the real flow resistance of the lines. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
37
Journal Issue
2
Journal Page Range
p. 147-150
ISSN
0258-0926

Optional Information

Notes
3 figs., 2 tabs., 2 refs.; http://dx.doi.org/10.13832/j.jnpe.2016.02.0147