Published September 1991
| Version v1
Journal article
Application of the GAMS-2000 hodoscopic spectrometer for triggering an installation for study on the neutral meson production
Creators
- 1. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR,
Description
System for analog signal summation of 1532 counters of the GAMS-200 hodoscopic spectrometer intended for fast (30 ns) determination of γ-quanta (electron) energy is described. The system is based on active summators connected into three summation cascades. Differential discriminator with regulated threshold and fast parallel analog-to-digital converter with noise suppression scheme are applied for amplitude analysis of signals under conditions of coherent noise. The system was used in the experiment on studying meson production by hadron central collisions at the 70 GeV accelerator of the Institute of High Energy Physics
Additional details
Additional titles
- Original title (Russian)
- Использование годоскопического спектрометра GAMS-2000 для запуска установка при исследовании образования нейтральных мезонов
Publishing Information
- Journal Title
- Pribory i Tekhnika Ehksperimenta
- Journal Issue
- no.5
- Journal Page Range
- p. 55-59.
- ISSN
- 0032-8162
- CODEN
- PRTEAJ
INIS
- Country of Publication
- Russian Federation
- Country of Input or Organization
- Russian Federation
- INIS RN
- 24007661
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ANALOG-TO-DIGITAL CONVERTERS; CALIBRATION; ELECTRON DETECTION; FLOWSHEETS; GAMMA DETECTION; HODOSCOPES; MAGNETIC SPECTROMETERS; MESON REACTIONS; PULSE DISCRIMINATORS; TRIGGER CIRCUITS
- Descriptors DEC
- CHARGED PARTICLE DETECTION; DETECTION; DIAGRAMS; DISCRIMINATORS; ELECTRONIC CIRCUITS; ELECTRONIC EQUIPMENT; EQUIPMENT; HADRON REACTIONS; INFORMATION; MEASURING INSTRUMENTS; NUCLEAR REACTIONS; PULSE CIRCUITS; RADIATION DETECTION; SPECTROMETERS