The results of field trials - closely monitored by scientists from Bristol University - in six radon contaminated houses in Street, Somerset, show that for dwellings with a contamination level of 200-1000 Becquerels per cubic metre (Bq/m3), installation and operation of a Nu-Aire DriMaster-R whole house ventilation system can reduce radon levels by an average factor of four to five - to well below the National Radiological Protection Board (NRPB) recommended safety level of 200 Bq/m3. For dwellings with a contamination level greater than 1000 Bq/m3, the DriMaster-R still provides a low-cost method of reducing even these high radon levels. (author)
Additional details
Additional titles
- Subtitle (English)
- University-monitored tests of Nu-Aire installation show drastically reduced levels
Publishing Information
- Journal Title
- Heating and Ventilating Engineer
- Journal Volume
- 63
- Journal Issue
- 702
- Series
- Heat. Vent. Eng.
- Journal Page Range
- 10
- ISSN
- 0260-1338
- CODEN
- HVENB
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 22003756
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- CONTAMINATION; HOUSES; INTEGRAL DOSES; RADON; SAFETY; UNITED KINGDOM
- Descriptors DEC
- BUILDINGS; DEVELOPED COUNTRIES; ELEMENTS; EUROPE; NONMETALS; RADIATION DOSES; RARE GASES