Lumbar spine radiography: lower organ dose with the use of PA projection

  • 1. University of Ljubljana, Faculty of Health Sciences, Medical Imaging and Radiotherapy Department, Zdravstvena pot 5, Ljubljana (Slovenia)

Description

The purpose of the research was to determine the effect of the posteroanterior (PA) patient position in lumbar spine imaging on effective dose and the absorbed organ dose. The study was performed on 100 patients that were referred to the lumbar spine radiography that were divided into two equal groups of 50. Body Mass Index, Dose AREA Product (DAP), exposure index (EXI), tube time-current (mAs), image field size and the source-patient distance were acquired for each patient. The entrance surface dose (ESD), the effective dose and the absorbed organ doses were calculated. There was no statistically significant difference in the BMI and EXI between the AP and PA projection. The results showed a significant reduction of ESD by 33% and the effective dose by 53% when the PA projection was used. Furthermore, there was a 64% average reduction of the absorbed organ doses to the selected organs. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncz057

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
186
Journal Issue
4
Journal Page Range
p. 507-512
ISSN
0144-8420

INIS

Country of Publication
United Kingdom
Country of Input or Organization
France
INIS RN
51102235
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DISTANCE; EFFECTIVE RADIATION DOSES; IMAGES; PATIENTS; VERTEBRAE
Descriptors DEC
BODY; DOSES; ORGANS; RADIATION DOSES; SKELETON

Optional Information

Notes
31 refs.