Application results of a prototype ultrasonic liquid film sensor to a 7 MPa steam-water two-phase flow experiment

  • 1. Hitachi, Ltd., Research and Development Group, Hitachi, Ibaraki (Japan)
  • 2. Hitachi-GE Nuclear Energy, Ltd., Hitachi, Ibaraki (Japan)

Description

A prototype ultrasonic liquid film sensor was applied to a high-temperature steam-water two-phase flow experiment. The liquid film sensor was vertically installed in a loop which was connected to HUSTLE, a multi-purpose steam source test facility. The hydraulic diameter of the measurement section was 9.4 mm. The output waveforms of the sensor were acquired with a digital oscilloscope. The fluid temperature and system pressure were kept at 288°C and 7.2 MPa, respectively, during the experiment. The pulse-echo method was used to calculate the liquid film thickness. The cross-correlation calculation was utilized to determine the time difference between the pulse reflected at the sensor surface and the pulse reflected at the liquid film surface. The time-averaged liquid film thicknesses were less than 0.055 mm in the annular flow condition. The increase of the time-averaged thickness was small with the change of the gas momentum flux. The film thicknesses measured with the sensor were compared with the past experimental results; the former were smaller than one-fourth of the thickness estimated as the mean film thickness. The comparison results suggested that the continuous liquid sublayer thickness was measured with the liquid film sensor. (author)

Availability note (English)

Available from http://dx.doi.org/10.1080/00223131.2015.1064040

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo)
Journal Volume
53
Journal Issue
4
Journal Page Range
p. 537-545
ISSN
0022-3131

Optional Information

Notes
13 refs., 11 figs., 1 tab.