Published 1987
| Version v1
Book
Design and operation of optimized high efficiency filter element test systems
Description
This paper discusses significant improvements in the design and operation of high efficiency filter test systems. The major areas discussed are the optimization of system hardware and the application of statistical analysis to expedite the test procedure. This has resulted in systems which can verify HEPA performance in 15 seconds, ULPA performance in 60 seconds, with low mass loading of non-DOP aerosols. Performance data are presented for two systems spanning a flow rate range of 1 to 65 m/sub 3//min (30 to 2000 cfm) and capable of determining fractional penetrations down to 10/sup -7/ (efficiencies up to 99.99999%) for particles from 0.1 to 1.0 micrometers
Additional details
Publishing Information
- Publisher
- Institute of Environmental Sciences.
- Imprint Place
- Mt. Prospect, IL (USA)
- ISBN
- 0-915414-27-9
- Imprint Title
- Proceedings of the 33rd annual technical meeting of the Institute of Environmental Sciences on environmental technology: Knowing the way
- Journal Page Range
- p. 439-451.
Conference
- Title
- Institute of Environmental Sciences annual meeting.
- Dates
- 4-8 May 1987.
- Place
- San Jose, CA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19105909
- Subject category
- S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AEROSOLS; COMPUTER CODES; EFFICIENCY; FILTERS; OPTIMIZATION; PARTICLES; PERFORMANCE TESTING; SPECIFICATIONS
- Descriptors DEC
- COLLOIDS; DISPERSIONS; SOLS; TESTING