Published 1996
| Version v1
Report
Open
Test policy optimization for a complex system: an application for the differential model for equivalent parameters (DMEP)
Creators
- 1. CEA Centre d'Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. de Mecanique et de Technologie
- 2. Electricite de France (EDF), 78 - Chatou (France)
Description
One of EDF's current priorities is the optimisation of the preventive maintenance in all French nuclear power stations. This optimisation involves a rationalization of the choice of equipments to be maintained and maintenance tasks to be carried out, as well as a judicious choice of intervals between these tasks. This work is being carried out in cooperation between EDF and the CEA (Atomic Energy Commission), and suggests a procedure to provide assistance in optimising intervals between maintenance tasks respecting a global unavailability target. This work is based on the DMEP. (authors). 2 refs., 2 figs
Availability note (English)
MF available from INIS under the Report Number.Files
28014139.pdf
Files
(153.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:fe701890a2568cff9e96288e8297b739
|
153.7 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 6 p.
- Report number
- CEA-CONF--12419
Conference
- Title
- ESREL'96.
- Dates
- 24-28 Jun 1996.
- Place
- Crete (Greece).
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 28014139
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DIESEL ENGINES; FAILURE MODE ANALYSIS; OPTIMIZATION; PWR TYPE REACTORS; REACTOR MAINTENANCE
- Descriptors DEC
- ENGINES; ENRICHED URANIUM REACTORS; HEAT ENGINES; INTERNAL COMBUSTION ENGINES; MAINTENANCE; POWER REACTORS; REACTORS; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS