There is a newer version of the record available.

Published December 2022 | Version v1
Journal article

A novel sandwich impedimetric immunosensor for detection of apolipoprotein-A1 based on the gold nanoparticle–hybridized mercapto-β-cyclodextrin-Pb(II) metal–organic framework

  • 1. Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, School of Pharmacy, China Pharmaceutical University, Nanjing, People's Republic of (China)
  • 2. Department of TCMs Pharmaceuticals, China Pharmaceutical University, Nanjing, People's Republic of (China)
  • 3. Department of Chemotherapy, Nanjing Medical University Affiliated Cancer Hospital, Cancer Institute of Jiangsu Province, Nanjing, People's Republic of (China)

Description

A novel sandwich electrochemical impedimetric immunosensor was proposed to detect apolipoprotein-A1 (Apo-A1), a common biomarker for bladder cancer. The molybdenum disulfide/graphene quantum dot (MoS2/GQD) nanocomposites were modified on the surface of a glassy carbon electrode (GCE) and used to immobilize the biotinylated antibody (Ab1) with the help of chitosan and glutaraldehyde (denoted as BSA/Ab1/CHIT/MoS2/GQD/GCE). Pb(II)-thiol-β-cyclodextrin metal–organic framework (denoted as Pb-MOF) was synthesized with lead metal ions and thiol-β-cyclodextrin ligands by a one-pot solvothermal method, and then, gold nanoparticles were modified on the surface of Pb-MOF (Pb-MOF-AuNPs) by Au–S bond, which was used as signal label for the recombinant antibody (Ab2). When the immunosensor of BSA/Ab1/CHIT/MoS2/GQD/GCE reacted with Apo-A1, Pb-MOF-AuNPs-Ab2/BSA was connected to the electrode when immunoreaction occurred, and an immune sandwich structure was formed, which led to significantly increased charge transfer resistance of electrochemical probe for ferrocyanide (II)/(III) within the frequency range 10−1 ~ 105 Hz at 5 mV amplitude and the potential of 0.180 V (vs. SCE). Based on this principle, the quantitative detection of Apo-A1 was established. The relative change of electrochemical resistance and the logarithmic value of Apo-A1 concentration showed a linear relationship with a linear coefficient of 0.9989 in the range 1.00 pg mL−1 and 1.00 μg mL−1 with the limit of detection of 0.30 pg mL−1. The selectivity, repeatability, and other performance of the proposed immunosensor were also investigated. The immunosensor was successfully applied to the detection of real serum and urine samples with recovery in the range 96.4 ~ 109.1% (RSD < 3.8%), indicating that it could be helpful for the clinical diagnosis of bladder cancer. Graphical abstract

Additional details

Publishing Information

Journal Title
Mikrochimica Acta
Journal Volume
190
Journal Issue
1
Journal Page Range
p. 1-11
ISSN
0026-3672

Optional Information

Copyright
Copyright (c) 2022 The Author(s), under exclusive licence to Springer-Verlag GmbH Austria, part of Springer Nature