Diagnostic efficacy and therapeutic impact of computed tomography in the evaluation of clinically suspected otosclerosis
- 1. King's College Hospital NHS Foundation Trust, Department of Neuroradiology, London (United Kingdom)
- 2. Department of Otolaryngology, Head and Neck Surgery, Auditory Implantation Centre, London (United Kingdom)
- 3. Department of Radiology, Guy's and St Thomas' NHS Foundation Trust, London (United Kingdom)
Description
To assess the diagnostic efficacy and therapeutic impact of CT in evaluating patients with clinically suspected otosclerosis. CT scans performed over a 5-year period for clinically suspected otosclerosis were retrospectively reviewed. CT diagnoses were correlated with subsequent surgical management. For otosclerosis positive cases, clinically significant extensions of otosclerosis were correlated with audiometry and the diagnosis was correlated with surgical findings. Of 259 CT studies, 46 % of patients were positive, 49 % negative and 5 % equivocal for otosclerosis. A relevant alternative CT diagnosis was evident in 33 % of the negative studies. One targeted surgery was performed for every four CT studies. CT outcome influenced the decision to perform stapedectomy in 41 % CT-positive versus 4 % CT-negative patients. CT-positive ears for otosclerosis could not be predicted from baseline clinical or audiometric criteria. Those with endosteal extension demonstrated lower bone conduction thresholds presurgically. The positive predictive value of CT diagnosis of otosclerosis was 100 %. CT demonstrated a high rate of clinically relevant diagnoses in both CT-positive and -negative for otosclerosis patients, and this frequently influenced surgical management. CT also added value by demonstrating relevant extensions of the otosclerotic foci, some of which were predictive of audiometric parameters. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-016-4446-8Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 27
- Journal Issue
- 3
- Journal Page Range
- p. 1195-1201
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 48038021
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AUDITORY ORGANS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC USES; EFFICIENCY; HZ RANGE; KHZ RANGE; SKELETAL DISEASES; SOUND WAVES; SURGERY; SYMPTOMS
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; FREQUENCY RANGE; MEDICINE; ORGANS; SENSE ORGANS; TOMOGRAPHY; USES