The study of the detection efficiency of the liquid scintillator for neutrino oscillation experiment
Creators
- 1. Visiting Professor of Institute of Physics, Taibei (China)
- 2. Chinese Academy of Sciences, Beijing (China). Inst. of High Energy Physics
- 3. Institute of Physics, Taibei (China)
Description
In order to provide the criteria for the detector and trigger logical design of Taiwan Neutrino Oscillation (TEXNON) experiment, the relationship of the positron detection efficiency with the construction of the detector and the trigger model have been investigated. Correspondent results have been obtained, such as the cell size of 15 x 15 cm2, single cell deposited energy threshold set at 55 keV, the 5 x 5 and 7 x 7 cells for triggering gamma ray, the positron detection is about 60% and 70% respectively. This set of parameters is recommended as the better choose of the detector design. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 27
- Journal Issue
- 1
- Journal Page Range
- p. 1-4
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 39039200
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- DESIGN; EFFICIENCY; GAMMA RADIATION; LIQUID SCINTILLATORS; NEUTRINO OSCILLATION; PARAMETRIC ANALYSIS; POSITRON DETECTION; SPECIFICATIONS; TAIWAN
- Descriptors DEC
- ASIA; CHARGED PARTICLE DETECTION; CHINA; DETECTION; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; ISLANDS; PHOSPHORS; RADIATION DETECTION; RADIATIONS
Optional Information
- Notes
- 3 figs., 2 tabs., 4 refs.