Quality assurance of environmental gamma radiation monitoring in Slovenia
- 1. Jofef Stefan Inst., Jamova 39, 1000 Ljubljana (Slovenia)
- 2. Slovenian Nuclear Safety Administration, Zelezna cesta 16, 1001 Ljubljana (Slovenia)
- 3. Ruder Boskovic Inst., Bijenicka 54, 10000 Zagreb (Croatia)
Description
Environmental gamma radiation monitoring established in Slovenia consists of a network of multifunctional gamma monitors (MFMs) based on pairs of Geiger-Mueller counters and a network of measuring sites with high-sensitive thermoluminescence dosemeters. The measuring points are evenly spread across Slovenia, located at the meteorological stations and more densely on additional locations around the Krsko NPP. The MFM network has a 2-fold function with one sensor used for the purpose of early warning system in near surroundings of the NPP and the other, more sensitive, for natural radiation monitoring. The paper summarises activities to establish quality assurance of the environmental gamma radiation measurements in Slovenia, with a critical view of the results in comparison with the international standards and recommendations. While the results of linearity and energy dependence tests were satisfying, on-field intercomparison showed that the inherent signal of one of the monitors (MFM) has to be taken into account in the range of environmental background radiation. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/nci380Additional details
Identifiers
- DOI
- 10.1093/rpd/nci380;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 121
- Journal Issue
- 2
- Journal Page Range
- p. 191-194
- ISSN
- 0144-8420
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 44017075
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S54: ENVIRONMENTAL SCIENCES;
- Descriptors DEI
- ALARM SYSTEMS; BACKGROUND RADIATION; COMPARATIVE EVALUATIONS; GAMMA RADIATION; GEIGER-MUELLER COUNTERS; KRSKO REACTOR; NATURAL RADIOACTIVITY; QUALITY ASSURANCE; QUALITY CONTROL; RADIATION MONITORING; RADIATION MONITORS; RECOMMENDATIONS; SENSORS; SLOVENIA; STANDARDS; THERMOLUMINESCENT DOSEMETERS; THERMOLUMINESCENT DOSIMETRY
- Descriptors DEC
- CONTROL; DOSEMETERS; DOSIMETRY; EASTERN EUROPE; ELECTROMAGNETIC RADIATION; ENRICHED URANIUM REACTORS; EUROPE; EVALUATION; IONIZING RADIATIONS; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MONITORING; MONITORS; POWER REACTORS; PWR TYPE REACTORS; RADIATION DETECTORS; RADIATIONS; RADIOACTIVITY; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 7 refs