Published November 10, 2010 | Version v1
Report

Incremental performance improvements for a surface-convergency H- ion source

Description

We discuss some of the interventions on LANSCE's surface-conversion negative-hydrogen ion sources to increase reliability; lifetime and output without any major re-design of the machine. LANSCE's source presently delivers a baseline 16 mA, 60 Hz, 12% duty factor beam. We describe how better quality control and processing of tungsten filaments allow the comfortable completion of 28-day run cycles, how improved temperature control of the ion source body yields an increased H- output, how higher input power through an additional filament allows operations at plasma densities while maintaining the filament lifetime and how adequate electrode biasing inside the source provide some control over the beam Twiss parameters on exit.

Additional details

Publishing Information

Imprint Pagination
10 p.
Report number
LA-UR--10-07614

Conference

Title
2. International Symposium on Negative Ions, Beams and Sources
Acronym
NIBS 2010
Dates
16 Nov 2010
Place
Takayama (Japan)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
43081300
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CESIUM; ELECTRODES; HYDROGEN IONS; ION SOURCES; LIFETIME; PERFORMANCE; PLASMA; PROCESSING; QUALITY CONTROL; RELIABILITY; TEMPERATURE CONTROL; TUNGSTEN
Descriptors DEC
ALKALI METALS; CHARGED PARTICLES; CONTROL; ELEMENTS; IONS; METALS; REFRACTORY METALS; TRANSITION ELEMENTS

Optional Information

Contract/Grant/Project number
AC52-06NA25396
Funding organization
US Department of Energy (United States)
Secondary number(s)