Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms
Creators
- 1. University Hospital Cologne, Department of Diagnostic and Interventional Radiology, Cologne (Germany)
Description
Aim of this study was to assess the artifact reduction in patients with orthopedic hardware in the spine as provided by (1) metal-artifact-reduction algorithms (O-MAR) and (2) virtual monoenergetic images (MonoE) as provided by spectral detector CT (SDCT) compared to conventional iterative reconstruction (CI). In all, 28 consecutive patients with orthopedic hardware in the spine who underwent SDCT-examinations were included. CI, O-MAR and MonoE (40-200 keV) images were reconstructed. Attenuation (HU) and noise (SD) were measured in order to calculate signal-to-noise ratio (SNR) of paravertebral muscle and spinal canal. Subjective image quality was assessed by two radiologists in terms of image quality and extent of artifact reduction. O-MAR and high-keV MonoE showed significant decrease of hypodense artifacts in terms of higher attenuation as compared to CI (CI vs O-MAR, 200 keV MonoE: -396.5HU vs. -115.2HU, -48.1HU; both p ≤ 0.001). Further, artifacts as depicted by noise were reduced in O-MAR and high-keV MonoE as compared to CI in (1) paravertebral muscle and (2) spinal canal - CI vs. O-MAR/200 keV: (1) 34.7 ± 19.0 HU vs. 26.4 ± 14.4 HU, p ≤ 0.05/27.4 ± 16.1, n.s.; (2) 103.4 ± 61.3 HU vs. 72.6 ± 62.6 HU/60.9 ± 40.1 HU, both p ≤ 0.001. Subjectively both O-MAR and high-keV images yielded an artifact reduction in up to 24/28 patients. Both, O-MAR and high-keV MonoE reconstructions as provided by SDCT lead to objective and subjective artifact reduction, thus the combination of O-MAR and MonoE seems promising for further reduction. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00256-017-2776-5Additional details
Identifiers
Publishing Information
- Journal Title
- Skeletal Radiology
- Journal Volume
- 47
- Journal Issue
- 2
- Journal Page Range
- p. 195-201
- ISSN
- 0364-2348
- CODEN
- SKRADI
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 49031749
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALGORITHMS; ATTENUATION; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC USES; IMAGE PROCESSING; ITERATIVE METHODS; KEV RANGE 100-1000; METALS; MORPHOLOGY; MUSCLES; SIGNAL-TO-NOISE RATIO; SKELETAL DISEASES; SPINAL CORD; SURGICAL MATERIALS; VERTEBRAE
- Descriptors DEC
- BODY; CALCULATION METHODS; CENTRAL NERVOUS SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DISEASES; ELEMENTS; ENERGY RANGE; KEV RANGE; MATERIALS; MATHEMATICAL LOGIC; MEDICAL SUPPLIES; NERVOUS SYSTEM; ORGANS; PROCESSING; SKELETON; TOMOGRAPHY; USES