Purification and Concentration of Gallium-68 via anion exchange method from a SnO2- Based Column Germanium-68/ Gallium-68 Generator

  • 1. Malaysian Nuclear Agency, Bangi, Kajang, Selangor (Malaysia), Medical Technology Div.
  • 2. National Cancer Institute, Putrajaya (Malaysia), Nuclear Medicine Dept.

Description

PET/CT Scan with 68Ga-labelled analogs is of increasing interest in Nuclear Medivcine and currently is being performed all over the world. However, such labelling procedure requires high purity and concentrated solutions of 68Ga. Here we report the purification and concentration of the aluate of SnO2-Based 68Ge/ 68Ga generators via the anion exchange method. Three different anion columns were selected to purify and concentrate the 68Ga eluates which are Chromafix, Oasis WAX and AG 1-X8 columns. The different anion columns were compared and evaluated in terms of their capability in adsorption and desorption of 68Ga from the generator. While the optimum molarity of Hydrochloric Acid (HCl) for highest 68Ga retention was also determined starting from the ranges of 4M to 7M of HCl. The results showed that the percentage of 68Ga retention or adsorption atarted to be plateau at molaruty of 5.5M for all three anion cartridges. One-way ANOVA analysis proved that there is no significant difference between 5.5M with 6.0M, 6.5M and 7.0M which means that the retention of 68Ga is equal at those molarities. At 5.5M, Chromafix and Oasis WAX cartridges showed the highest retention of 68Ga which is 98.30 %. The lowest 68Ga retention was gained by AG 1-X8 column which is 97.07 %. While for desorption of 68Ga, the highest percentage was obtained by using Oasis WAX cartridges which is 70.49 % followed by Chromafix which is 70.36 %. The lowest desorption of 68Ga was obtained by using AG 1-X8 column which is only 58.56 %. Therefore, from this study, the most suitable cartridge and HCl molarity that should be applied in purification and concentration of Gallium-68 eluate from a SnO2 based 68Ge/ 68Ga generator is Oasis WAX column with a HCl molarity of 5.5M respectively. (author)

Additional details

Publishing Information

Journal Title
Journal of Nuclear and Related Technologies
Journal Volume
12
Journal Issue
1
Journal Page Range
p. 1-18
ISSN
1823-0180

Optional Information

Notes
5 tabs. 4 figs.