Published June 1989 | Version v1
Report Restricted

Nonuniformities in organic liquid ionization calorimeters

Creators

  • 1. Lawrence Berkeley Lab., CA (USA)

Description

Hermeticity and uniformity in SSC calorimeter designs are compromised by structure and modularity. Some of the consequences of the cryogenic needs of liquid argon calorimetry are relatively well known. If the active medium is an organic liquid (TMP, TMS, etc.), a large number of independent liquid volumes is needed for safety and for rapid liquid exchange to eliminate local contamination. Modular construction ordinarily simplifies fabrication, assembly, handling and preliminary testing at the price of additional walls, other dead regions and many nonuniformities. Here we examine ways of minimizing the impact of some generic nonuniformities on the quality of calorimeter performance. 6 refs., 7 figs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 - OSTI as DE89015346; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
7 p.
Report number
LBL--27327

Conference

Title
Workshop on calorimetry for the SSC.
Dates
13-17 Mar 1989.
Place
Tuscaloosa, AL (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
20086036
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
IONIZATION; ORGANIC COMPOUNDS; PERFORMANCE; SHOWER COUNTERS; SPECIFICATIONS; SUPERCONDUCTING SUPER COLLIDER
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; MEASURING INSTRUMENTS; RADIATION DETECTORS; STORAGE RINGS; SYNCHROTRONS

Optional Information

Contract/Grant/Project number
Contract AC03-76SF00098
Secondary number(s)
CONF-890379--13.