Nonuniformities in organic liquid ionization calorimeters
Description
Hermeticity and uniformity in SSC calorimeter designs are compromised by structure and modularity. Some of the consequences of the cryogenic needs of liquid argon calorimetry are relatively well known. If the active medium is an organic liquid (TMP, TMS, etc.), a large number of independent liquid volumes is needed for safety and for rapid liquid exchange to eliminate local contamination. Modular construction ordinarily simplifies fabrication, assembly, handling and preliminary testing at the price of additional walls, other dead regions and many nonuniformities. Here we examine ways of minimizing the impact of some generic nonuniformities on the quality of calorimeter performance. 6 refs., 7 figs
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 - OSTI as DE89015346; US Govt. Printing Office Dep.
Files
Additional details
Publishing Information
- Imprint Pagination
- 7 p.
- Report number
- LBL--27327
Conference
- Title
- Workshop on calorimetry for the SSC.
- Dates
- 13-17 Mar 1989.
- Place
- Tuscaloosa, AL (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 20086036
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- IONIZATION; ORGANIC COMPOUNDS; PERFORMANCE; SHOWER COUNTERS; SPECIFICATIONS; SUPERCONDUCTING SUPER COLLIDER
- Descriptors DEC
- ACCELERATORS; CYCLIC ACCELERATORS; MEASURING INSTRUMENTS; RADIATION DETECTORS; STORAGE RINGS; SYNCHROTRONS
Optional Information
- Contract/Grant/Project number
- Contract AC03-76SF00098
- Secondary number(s)
- CONF-890379--13.