Published September 2012 | Version v1
Journal article

Volumetric modulated arc therapy for nasopharyngeal carcinoma: A dosimetric comparison with TomoTherapy and step-and-shoot IMRT

  • 1. Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China)
  • 2. Division of Radiation Oncology, Departments of Oncology, National Taiwan University Hospital, Taipei, Taiwan (China)
  • 3. Graduate Institute of Oncology, National Taiwan University, Taipei, Taiwan (China)
  • 4. Graduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei, Taiwan (China)
  • 5. Institute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei, Taiwan (China)
  • 6. Graduate Institute of Electrical Engineering, National Taiwan University, Taipei, Taiwan (China)

Description

Purpose: Volumetric modulated arc therapy (VMAT), a novel technique, employs a linear accelerator to conduct dynamic modulation rotation radiotherapy. The goal of this study was to compare VMAT with helical tomotherapy (HT) and step-and-shoot intensity-modulated radiation therapy (IMRT) for nasopharyngeal carcinoma (NPC) patients with regard to the sparing effect on organs at risk (OARs), dosimetric quality, and efficiency of delivery. Materials and methods: Twenty patients with NPC treated by HT were re-planned by VMAT (two arcs) and IMRT (7–9 fields) for dosimetric comparison. The target area received three dose levels (70, 60, and 54 Gy) in 33 fractions using simultaneous integrated boosts technique. The Philips Pinnacle Planning System 9.0 was adopted to design VMAT, using SmartArc as the planning algorithm. For a fair comparison, the planning target volume (PTV) coverage of the 3 plans was normalized to the same level. Dosimetric comparisons between VMAT, HT, and IMRT plans were analyzed to evaluate (1) coverage, homogeneity, and conformity of PTV, (2) sparing of OARs, (3) delivery time, and (4) monitor units (MUs). Results: The VMAT, HT, and IMRT plans had similar PTV coverage with an average of 96%. There was no significant difference between VMAT and HT in homogeneity, while the homogeneity indices of VMAT (1.06) and HT (1.06) were better than IMRT plans (1.07, p < 0.05). HT plans provided a better conformity index (1.17) than VMAT (1.28, p = 0.01) and IMRT (1.36, p = 0.02). When compared with IMRT, VMAT and HT had a better sparing effect on brain stem and spinal cord (p < 0.05). The effect of parotid sparing was similar between VMAT (mean = 26.3 Gy) and HT (mean = 27.5 Gy), but better than IMRT (mean = 31.3 Gy, p < 0.01). The delivery time per fraction for VMAT (5.7 min) were much lower than for HT (9.5 min, p < 0.01) and IMRT (9.2 min, p < 0.01). Conclusions: Our results indicate that VMAT provides better sparing of normal tissue, homogeneity, and conformity than IMRT, and shorter delivery time than HT.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radonc.2011.11.017

Additional details

Identifiers

DOI
10.1016/j.radonc.2011.11.017;
PII
S0167-8140(11)00716-X;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
104
Journal Issue
3
Journal Page Range
p. 324-330
ISSN
0167-8140
CODEN
RAONDT

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.