Published January 27, 2014 | Version v1
Journal article

Rational strategy for characterization of nanoscale particles by asymmetric-flow field flow fractionation: A tutorial

Description

Graphical abstract: -- Highlights: •Underlying theory and critical parameters are introduced. •A rational workflow is proposed to optimize and refine A4F methods. •Specific optimization steps and validation parameters are delineated. •Pedagogical examples are provided to demonstrate the process. •Use and relevance of different detection modalities is addressed. -- Abstract: This tutorial proposes a comprehensive and rational measurement strategy that provides specific guidance for the application of asymmetric-flow field flow fractionation (A4F) to the size-dependent separation and characterization of nanoscale particles (NPs) dispersed in aqueous media. A range of fractionation conditions are considered, and challenging applications, including industrially relevant materials (e.g., metal NPs, asymmetric NPs), are utilized in order to validate and illustrate this approach. We demonstrate that optimization is material dependent and that polystyrene NPs, widely used as a reference standard for retention calibration in A4F, in fact represent a class of materials with unique selectivity, recovery and optimal conditions for fractionation; thus use of these standards to calibrate retention for other materials must be validated a posteriori. We discuss the use and relevance of different detection modalities that can potentially yield multi-dimensional and complementary information on NP systems. We illustrate the fractionation of atomically precise nanoclusters, which are the lower limit of the nanoscale regime. Conversely, we address the upper size limit for normal mode elution in A4F. The protocol for A4F fractionation, including the methods described in the present work is proposed as a standardized strategy to realize interlaboratory comparability and to facilitate the selection and validation of material-specific measurement parameters and conditions. It is intended for both novice and advanced users of this measurement technology

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2013.11.021

Additional details

Identifiers

DOI
10.1016/j.aca.2013.11.021;
PII
S0003-2670(13)01440-2;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
809
Journal Page Range
p. 9-24
ISSN
0003-2670
CODEN
ACACAM

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45040850
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
CALIBRATION; DETECTION; FRACTIONATION; NANOSTRUCTURES; OPTIMIZATION; PARTICLES; POLYSTYRENE; VALIDATION
Descriptors DEC
MATERIALS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; PETROCHEMICALS; PETROLEUM PRODUCTS; PLASTICS; POLYMERS; POLYOLEFINS; POLYVINYLS; SEPARATION PROCESSES; SYNTHETIC MATERIALS; TESTING

Optional Information

Copyright
Copyright (c) 2013 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.