Published September 17, 2014 | Version v1
Journal article

Thermal Analysis of ZPPR High Pu Content Stored Fuel

  • 1. Idaho National Lab. (INL), Idaho Falls, ID (United States)

Description

The Zero Power Physics Reactor (ZPPR) operated from April 18, 1969, until 1990. ZPPR operated at low power for testing nuclear reactor designs. This paper examines the temperature of Pu content ZPPR fuel while it is in storage. Heat is generated in the fuel due to Pu and Am decay and is a concern for possible cladding damage. Damage to the cladding could lead to fuel hydriding and oxidizing. A series of computer simulations were made to determine the range of temperatures potentially occuring in the ZPPR fuel. The maximum calculated fuel temperature is 292°C (558°F). Conservative assumptions in the model intentionally overestimate temperatures. The stored fuel temperatures are dependent on the distribution of fuel in the surrounding storage compartments, the heat generation rate of the fuel, and the orientation of fuel. Direct fuel temperatures could not be measured but storage bin doors, storage sleeve doors, and storage canister temperatures were measured. Comparison of these three temperatures to the calculations indicates that the temperatures calculated with conservative assumptions are, as expected, higher than the actual temperatures. The maximum calculated fuel temperature with the most conservative assumptions is significantly below the fuel failure criterion of 600°C (1,112°F)

Availability note (English)

Available from: DOI:10.1155/2014/402351 ; DOE Accepted Manuscript full text, or the publishers Best Available Version will be available free of charge after the embargo period from OSTI using http://www.osti.gov/pages/biblio/1179103

Additional details

Publishing Information

Journal Title
International Journal of Nuclear Energy (Print)
Journal Volume
2014
Journal Page Range
vp.
ISSN
2356-7066

Optional Information

Contract/Grant/Project number
AC07-05ID14517
Funding organization
USDOE Office of Nuclear Energy (United States)
Secondary number(s)
INL/JOU--14-30991; OSTIID--1179103