An initial randomised study assessing free-breathing CCTA using 320-detector CT
- 1. Dong-A University College of Medicine, Department of Radiology, Busan (Korea, Republic of)
- 2. Kyungpook National University and Hospital, Department of Radiology, Daegu (Korea, Republic of)
- 3. Dong-A University College of Medicine, Department of Preventive Medicine, Busan (Korea, Republic of)
Description
To evaluate the feasibility of free-breathing coronary computed tomography angiography (CCTA) in adults using with a 320-detector multidetector CT (MDCT). In 74 patients who underwent CCTA, 37 CCTA examinations were performed during free-breathing, and the remaining 37 CCTA examinations were produced with the standard breath-holding method. The quality scores for 16 segments of all coronary arteries were analysed and defined as: 1 (excellent), 2 (good), and 3 (poor). The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and effective radiation dose of each image were compared between the two methods. No significant differences were observed in the quality scores between the breath-holding and free-breathing methods (1.10 ± 0.31 vs. 1.12 ± 0.33; P = 0.443). The SNR and CNR were not significantly different between the two methods. The overall mean effective radiation dose revealed no significant difference between the two methods (P = 0.585). Free-breathing CCTA using 320-detector MDCT showed no significant difference in image quality compared with standard breath-holding CCTA. For patients with difficulties of breath-holding or non-negligible apnoea-related heart rate variability, free-breathing CCTA can be an alternative solution for coronary artery evaluation. circle Cardiac CT is becoming widely used and some patients are inevitably breathless. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-012-2703-zAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 23
- Journal Issue
- 5
- Journal Page Range
- p. 1199-1209
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 44105740
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ADULTS; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CORONARIES; HEART; RADIATION DETECTORS; RADIATION DOSES; RANDOMNESS; RESPIRATION; SIGNAL-TO-NOISE RATIO; STATISTICS
- Descriptors DEC
- AGE GROUPS; ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DIMENSIONLESS NUMBERS; DOSES; EVALUATION; MATHEMATICS; MEASURING INSTRUMENTS; ORGANS; TOMOGRAPHY