Published July 1991 | Version v1
Journal article

An AMS electrostatic deflector

  • 1. China Inst. of Atomic Energy, Beijing

Description

The design, set-up and test of an electrostatic deflector used in the accelerator mass spectrometer (AMS) are described. The main characteristics of electrostatic deflector are as follows: the deflection angle is 15 deg C; the radius of curvature and length is 360 cm and 100 cm, respectively; the gap between the electrodes is 3 cm; the positive and negative voltage no the two electrodes reach 92.4 kV and 80 kV, respectively, and the electric field is 57.5 kV/cm

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
2
Journal Issue
4
Journal Page Range
p. 29-33.
ISSN
1000-6931
CODEN
YKJIEZ

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
24007614
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
CHLORINE ISOTOPES; DIVERTORS; ELECTRIC POTENTIAL; ELECTRODES; ELECTROSTATIC ANALYZERS; MASS SPECTROMETERS
Descriptors DEC
BEAM ANALYZERS; MEASURING INSTRUMENTS; SPECTROMETERS