Historical event: the best reload of CLV

Description

The present work will describe how the Laguna Verde Central advances to achieve the excellence in the evaluations of WANO, in one of their two important concepts that have to improve to aspire to that qualification, in Collective Dose of the Personnel and in the duration of the periods of the fuel reloads. The result of the 11th Fuel reload of the Unit 1 that begins September 11, 2005 and concludes on October 10, 2005, came out in 29.5 days, being the best in the history of the CLV. It critical route (most large duration activities) it was the bigger maintenance of the main generator, having like challenge that if the program was completed or decreased the time, the Laguna Verde Central it would be placed in the threshold of the qualification of Excellency. With this vision the technicians of the Power station in previous meetings, determined to improve the maneuvers recommended by the manufacturing Mitsubishi (Japanese Company) for the disassembly and assembly of the rotor that it has a weight of 120 tons, same that for their great weight make difficult the maneuver. This maintenance is carried out every five years, highlighting that in its previous maintenance it was in reload of 17 hours in its retirement, same that it was to improve. The changes to the instructions of Mitsubishi for the retirement of the rotor are: the use of synthetic slings instead of steel strobes that needed to use of neoprene and wooden staves to protect the rotor and a system of pulleys instead of differential of chain, being 3 hours in the retirement of the rotor, instead of 17 hours that it lasted previously. It is also excellent that it decreased of six necessary people for the movement of the rotor, to a one person. The reduction of effort was shown in pictures, like instead of the chain differential, they put on steel strobes with pulleys. To give the force of the movement it was used a hoisting machine. The two fixed support points were changed in supports with simple pulleys. Instead of the steel slings of 2 3/4 inches it was used of the synthetic fiber slings type band. In this way could be observe the aluminum and glass cubicle that it gave a clean atmosphere, as well as other details that allowed these improvements. (Author)

Availability note (English)

Available from INIS in electronic form

Files

38002942.pdf

Files (1.7 MB)

Name Size Download all
md5:e10e6d09b35814f1e42f559964bd87d8
1.7 MB Preview Download

Additional details

Additional titles

Original title (Spanish)
Hecho historico: la mejor recarga de CLV

Publishing Information

Imprint Pagination
10 p.
Report number
INIS-MX--2103

Conference

Title
1. american congress of the IRPA; 7. regional congress of radiological and nuclear safety; 24. annual meeting of the SMSR; 17. annual congress of the SNM
Original Conference Title
Retos y tendencias para el continente americano respecto a la proteccion radiologica, la seguridad nuclear y el ambiente
Dates
3-8 Sep 2006
Place
Acapulco, Gro. (Mexico)