Published December 2013 | Version v1
Journal article

Analysis of ITER poloidal field converter reliability

  • 1. School of Electric and Automatic Engineering, Hefei University of Technology, Hefei (China)
  • 2. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei (China)

Description

The poloidal field (PF) converter belongs to the critical systems of ITER, thus its reliability and availability should maintain a high state through the two decades operation life of ITER. This paper is aiming at improving these two abilities with the RAMI (Reliability, Availability, Maintainability and Inspectability) analysis method. The system functional breakdown is performed at first, then the reliability model is established based on it. The initial reliability and availability of the PF converter is obtained by analysing this model. Finally, by improving the reliability and availability of subsystems, the scheme of the PF converter satisfied the requirements of ITER. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Fusion and Plasma Physics
Journal Volume
33
Journal Issue
4
Journal Page Range
p. 348-353
ISSN
0254-6086

Optional Information

Notes
7 figs., 6 tabs., 7 refs.