Description
The poloidal field (PF) converter belongs to the critical systems of ITER, thus its reliability and availability should maintain a high state through the two decades operation life of ITER. This paper is aiming at improving these two abilities with the RAMI (Reliability, Availability, Maintainability and Inspectability) analysis method. The system functional breakdown is performed at first, then the reliability model is established based on it. The initial reliability and availability of the PF converter is obtained by analysing this model. Finally, by improving the reliability and availability of subsystems, the scheme of the PF converter satisfied the requirements of ITER. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Fusion and Plasma Physics
- Journal Volume
- 33
- Journal Issue
- 4
- Journal Page Range
- p. 348-353
- ISSN
- 0254-6086
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 48045659
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- AVAILABILITY; BREAKDOWN; DC TO DC CONVERTERS; ITER TOKAMAK; MAGNETIC FIELDS; OPERATION; POWER SUPPLIES; RELIABILITY
- Descriptors DEC
- CLOSED PLASMA DEVICES; ELECTRICAL EQUIPMENT; ELECTRONIC EQUIPMENT; EQUIPMENT; THERMONUCLEAR DEVICES; THERMONUCLEAR REACTORS; TOKAMAK DEVICES; TOKAMAK TYPE REACTORS
Optional Information
- Notes
- 7 figs., 6 tabs., 7 refs.