Published June 15, 1984
| Version v1
Report
Open
Event parameters - fixed target
Description
This subgroup has focussed on detectors for fixed target experiments which have full azimuthal coverage. The general scope of the working group was to consider (1) the configuration of an idealized detector, and (2) various configurations of practical detectors that could be implemented on a relatively short time scale. The second category includes possible upgrades and modifications of existing experimental facilities. Beams of both 15 GeV/A sulphur at the AGS and 200 GeV/A oxygen at the SPS were considered
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE84014817.Files
16008965.pdf
Files
(182.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:f56797259db2aa8af468ee2cdafbfb2b
|
182.0 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 7 p.
- Report number
- BNL--34952
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16008965
- Subject category
- S73: NUCLEAR PHYSICS AND RADIATION PHYSICS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- COMPARATIVE EVALUATIONS; HEAVY ION REACTIONS; RADIATION DETECTORS; SHOWER COUNTERS; STREAMER SPARK CHAMBERS
- Descriptors DEC
- GAS TRACK DETECTORS; MEASURING INSTRUMENTS; NUCLEAR REACTIONS; SPARK CHAMBERS